Variation

Influence of elbow angle on the reliability and validity of bioelectrical impedance analysis

Published on: 23rd November, 2017

OCLC Number/Unique Identifier: 7286351075

Hand-to-hand bioelectrical impedance (HH BIA) is a low-cost method to estimate percent body fat (%BF). The BIA method is consistently reliable, but questions on validity remain. We have observed anecdotally that elbow position can render consistently different measures of %BF while using HH BIA, thus leading to the question: Does elbow angle influence the validity of measures derived using HH BIA? The purpose of this study was to assess the effect of elbow position (i.e., IN=flexed to 90° versus OUT=fully extended) on the reliability of HH BIA on 44 male and 24 female healthy adults (age=21±2 yrs, BMI=23±3). An additional aim was to assess the validity of the HH BIA %BF on a subset of subjects (n=12) using air displacement plethysmography (BOD POD®) as the criterion measure. The IN position was ~4%BF lower than the OUT position for HH BIA (p=0.05, effect size=0.67). Measures of %BF for both trials for the IN [intraclass correlation coefficient (ICC)=0.99, coefficient of variation (CV)=2.99%] and OUT (ICC=0.99, CV=1.48%) conditions were highly reliable. On the subsample, the OUT (18.3±6.7 %BF) position exceeded both the IN (14.5±7.4 %BF) and the BOD POD® (16.1±7.8 %BF) measures (p<0.05); however, IN and BOD POD® measures of %BF did not differ (p=0.21). These findings support that HH BIA is a reliable measure at both elbow positions; however, %BF estimations vary considerably (~4%) with respect to the criterion measure depending on elbow position. The OUT position was found to overestimate criteria %BF. Further research may reveal an optimum elbow angle position for HH BIA estimates of %BF.
Cite this ArticleCrossMarkPublonsHarvard Library HOLLISGrowKudosResearchGateBase SearchOAI PMHAcademic MicrosoftScilitSemantic ScholarUniversite de ParisUW LibrariesSJSU King LibrarySJSU King LibraryNUS LibraryMcGillDET KGL BIBLiOTEKJCU DiscoveryUniversidad De LimaWorldCatVU on WorldCat

Procedure utilization, latency and mortality: Weekend versus Weekday admission for Myocardial Infarction

Published on: 19th May, 2017

OCLC Number/Unique Identifier: 7286355059

Background: Due to variations in hospital protocols and personnel availability, individuals with myocardial infarction admitted on the weekend may be less likely to receive invasive procedures, or may receive them with a greater latency than those admitted during the week. Whether or not this occurs, and translates into a difference in outcomes is not established. Method: Using the Nationwide Inpatient Sample (2008-2011) database, we identified all patients admitted with a principle diagnosis of acute myocardial infarction. They were stratified by weekend or weekday admission. Baseline clinical characteristics, procedure utilization and latency to procedure were compared, and logistic regression models were constructed to assess the relationship between these variables and in-hospital mortality. Results: Patient demographics and provider-related characteristics (hospital type, geography) were similar between weekend and weekday admission for myocardial infarction. Adjusted for covariates, we found that the odds of mortality for a weekend admission are 5% greater than for a weekday admission (OR: 1.05; 95% CI: 1.01, 1.09, p=0.009). For the utilization of an invasive procedure, we found that the odds of receiving a procedure for a weekend admission were 12% less than the odds for a weekday admission, adjusted for the other covariates (OR: 0.88; 95% CI: 0.86, 0.91, p<0.001). In addition, we found that the time to procedure was an average of 0.18 days (4.32 hours) longer for weekend admissions compared to weekday admissions (95% CI: 0.16, 0.20, p<0.001). However, we did not observe a significant difference in the overall length of stay for weekend and weekday admissions (0.004 days; 95% CI: -0.04, 0.05, p=0.87). Conclusion: In a large and diverse subset of patients admitted with myocardial infarction, weekend admission was associated with fewer procedures, increased latency to those procedures, and a non-significant trend towards greater in adjusted in-hospital mortality.
Cite this ArticleCrossMarkPublonsHarvard Library HOLLISGrowKudosResearchGateBase SearchOAI PMHAcademic MicrosoftScilitSemantic ScholarUniversite de ParisUW LibrariesSJSU King LibrarySJSU King LibraryNUS LibraryMcGillDET KGL BIBLiOTEKJCU DiscoveryUniversidad De LimaWorldCatVU on WorldCat

Hyperkalemia: An archenemy in emergency medicine. Description of two case reports

Published on: 5th November, 2018

OCLC Number/Unique Identifier: 7929242579

Potassium is an important ion capable to maintain intra-extracellular electric gradient. Variations in the intra-extracellular ionic flow may alter cells functions, skeletal and smooth muscle contractility and electric activity of myocardial cells. In this study we demonstrated that high level of serum potassium may be associated with cardiac and neurological life-threatening diseases. We describe two case reports in which one patient, chronic hemodialysed, presented with cardiogenic shock in setting of hyperkalemia; the other, with end-stage kidney disease, showed a flaccid paralysis associated to high level of serum potassium during potassium sparing diuretic therapy. Emergency haemodialysis was performed with a complete remission of the clinical manifestations. Indeed, the use of simply diagnostic instruments such as serum electrolyte assay and electrocardiographic study (ECG) are helpful in clinical practice solving in timely serious complications due to hyperkalemia.
Cite this ArticleCrossMarkPublonsHarvard Library HOLLISGrowKudosResearchGateBase SearchOAI PMHAcademic MicrosoftScilitSemantic ScholarUniversite de ParisUW LibrariesSJSU King LibrarySJSU King LibraryNUS LibraryMcGillDET KGL BIBLiOTEKJCU DiscoveryUniversidad De LimaWorldCatVU on WorldCat

Is there an ideal blood pressure during cardiopulmonary bypass to prevent postoperative cerebral injury? – What does the recent evidence say?

Published on: 21st November, 2018

OCLC Number/Unique Identifier: 7943236620

Post cardiac surgery stroke is a devastating complication with an incidence as high as 50%1. The association between intra-operative mean arterial blood pressure (MAP- better called linear blood pressure) during cardiopulmonary bypass (CPB) and the development of postoperative stroke-as diagnosed by neuroimaging- and of cognitive dysfunction (POCD) is controversial. This is due to differences in the study populations, stroke assessment tools, operation and conduction of MAPs, variations in neurocognitive testing and duration of follow up. As a result there is a gap in the knowledge on an ideal MAP as a preventive measure of post CPB stroke and POCD.
Cite this ArticleCrossMarkPublonsHarvard Library HOLLISGrowKudosResearchGateBase SearchOAI PMHAcademic MicrosoftScilitSemantic ScholarUniversite de ParisUW LibrariesSJSU King LibrarySJSU King LibraryNUS LibraryMcGillDET KGL BIBLiOTEKJCU DiscoveryUniversidad De LimaWorldCatVU on WorldCat

Anomalies of coronary artery origin: About two cases

Published on: 13th September, 2019

OCLC Number/Unique Identifier: 8270707766

Anomalies of coronary artery origin are congenital malformations characterized by the abnormal birth of a coronary artery from the controlateral coronary aortic sinus (birth of the left coronary artery from the right sinus or birth of the right coronary artery from the left sinus). The artery concerned has an abnormal initial path between the aorta and the pulmonary artery; this segment is most often intramural, in the aortic wall. They are rare with a prevalence (0.1% to 0.3% of the population). They pose a high risk of sudden stress death related to exercise myocardial ischemia. The most common mode of discovery is aborted sudden death, but sometimes fortuitously. The contribution of multi-round CT is described for the positive diagnosis of these anatomical variations, sometimes delicate in coronary angiography, but also for the distinction between “benign” and “malignant” forms, potentially responsible for myocardial ischemia. Treatment is usually surgical in symptomatic forms. We report the cases of two patients with coronary connection abnormalities discovered in adulthood.
Cite this ArticleCrossMarkPublonsHarvard Library HOLLISGrowKudosResearchGateBase SearchOAI PMHAcademic MicrosoftScilitSemantic ScholarUniversite de ParisUW LibrariesSJSU King LibrarySJSU King LibraryNUS LibraryMcGillDET KGL BIBLiOTEKJCU DiscoveryUniversidad De LimaWorldCatVU on WorldCat

Inter-Observer Variability of a Commercial Patient Positioning and Verification System in Proton Therapy

Published on: 6th February, 2017

OCLC Number/Unique Identifier: 7286354964

Purpose:Accurate patient positioning is crucial in radiation therapy. To fully benefit from the preciseness of proton therapy, image guided patient positioning and verification system is typically utilized in proton therapy. The purpose of this study is to evaluate the inter-observer variability of image alignment using a commercially available patient positioning and verification system in proton therapy. Methods:The VeriSuite patient positioning and verification system (MedCom GmbH, Darmstadt, Germany) provides a six degrees of freedom correction vector by registering two orthogonal x-ray images to digitally reconstructed radiograph (DRR) images that are rendered in real time from the planning computed tomography (CT) images. Six cases of various disease sites, including brain, head & neck, lung, prostate, pelvis, and bladder, were used in this study. For each case, the planning CT images and a daily orthogonal x-ray portal image pair were loaded into the VeriSuite system. The same set of x-ray images and CT images for each case were reviewed and aligned separately by each of the 10 radiation therapist, following the clinical procedure for the corresponding disease site. The resulting correction vectors were then recorded and analyzed. Results:Our study shows that the inter-observer variation (One standard deviation) in image alignment using the VeriSuite system ranged from 1.2 to 2.0 mm for translational correction and from 0.6 to 1.3 degrees for rotational correction for the six cases. The use of fiducial markers for prostate patient alignment achieved the least inter-observer variation while the bladder case produced the largest. Conclusions:Inter-observer variation in image alignment could be relatively large, depending on the complexity of patient anatomy, image alignment approach, and user experience and software limitations. Automatic registration and fiducial markers could potentially be used to align patient more accurately and consistently. To ensure adequate tumor coverage in proton therapy, inter-observer variability in patient alignment should be carefully evaluated and accounted for in patient setup uncertainty analysis and treatment planning margin determination.
Cite this ArticleCrossMarkPublonsHarvard Library HOLLISGrowKudosResearchGateBase SearchOAI PMHAcademic MicrosoftScilitSemantic ScholarUniversite de ParisUW LibrariesSJSU King LibrarySJSU King LibraryNUS LibraryMcGillDET KGL BIBLiOTEKJCU DiscoveryUniversidad De LimaWorldCatVU on WorldCat

An analysis of wild animals with respect to French Ethics and Law

Published on: 9th May, 2019

OCLC Number/Unique Identifier: 8163878958

Before discussing the crux of the matter, it is important to understand what “wild” signifies and the characteristics that define a wild animal. As contrasted to domesticated animals, a wild animal can be defined as an animal living freely in his natural habitat, independently of Man. These animals are only exposed to variations in the biological equilibrium, to the imperatives of their genetic program and live in a habitat that gives them the possibility of expressing it themselves. However, this definition is very narrow as there exist a number of species of wild animals that don’t live freely in their natural habitat. These animals are constrained by Man, who by creating a relationship of dependence, controls them and in turn becomes responsible for their sustenance. In such a situation, their habitat is no more their natural habitat but than which has been imposed on them by Man; such animals are said to be “held in captivity” or even “tamed”. In short, when talking about law and ethics related to wild animals, there are two things to be taken into account: wild animals that live in the wild and wild animals that live held in captivity by Man.
Cite this ArticleCrossMarkPublonsHarvard Library HOLLISGrowKudosResearchGateBase SearchOAI PMHAcademic MicrosoftScilitSemantic ScholarUniversite de ParisUW LibrariesSJSU King LibrarySJSU King LibraryNUS LibraryMcGillDET KGL BIBLiOTEKJCU DiscoveryUniversidad De LimaWorldCatVU on WorldCat

Prevalence and seasonal variations of eggs of gastrointestinal nematode parasites of goats from smallholder farms in Mozambique

Published on: 23rd July, 2019

OCLC Number/Unique Identifier: 8206561393

A survey was carried out to determine the prevalence and seasonal variations of eggs of gastrointestinal nematodes in goats in four provinces of Mozambique, from November 2016 to October 2017 in Tete and Cabo Delgado, and from November 2016 to October 2018 in Maputo and Gaza. In each province, flocks were selected from both lowlands, located within the valleys of the rivers, and uplands which are located outside the valleys. Faecal samples were collected at monthly intervals to monitor faecal egg counts fluctuations. The modified McMaster technique was used for quantitative analysis of nematode eggs and for detecting cestode eggs in faecal samples. The sedimentation technique for detecting trematode eggs in faecal samples was used. A total of 2 703 samples were examined for nematode eggs and 2 587 for trematode eggs. Faecal examination indicated that between 18% and 100% of goats sampled were infected with gastro-intestinal nematodes. The prevalence varied according to the season of the year and the ecological conditions. The highest prevalence and worm egg counts were recorded at about the peak of the rainy season. Strongyloides papillosus, Calicophoron spp., Fasciola spp. and Schistosoma mattheei eggs were also found. Moniezia expansa and Moniezia benedeni eggs were found in all the four study areas but its prevalence was low and irregular. Based on the results of this study, which showed a clear seasonal pattern, strategic anthelmintic medications to effectively control helminth infections in goats in the different ecological zones of Mozambique are suggested.
Cite this ArticleCrossMarkPublonsHarvard Library HOLLISGrowKudosResearchGateBase SearchOAI PMHAcademic MicrosoftScilitSemantic ScholarUniversite de ParisUW LibrariesSJSU King LibrarySJSU King LibraryNUS LibraryMcGillDET KGL BIBLiOTEKJCU DiscoveryUniversidad De LimaWorldCatVU on WorldCat

Evaluation of ImageJ for Relative Bone Density Measurement and Clinical Application

Published on: 15th December, 2016

OCLC Number/Unique Identifier: 7286423139

The main method for evaluation of healing processes of the jaws in oral and maxillofacial surgery are radiological diagnostics. Quantitative description is possible by measuring the relative bone density, which puts the mean grey value of a certain area in relation to the surrounding bone tissue. In this research the intra- and interindividual variability is determined for this method and a standard operation procedure is elaborated. Therefore ten panoramic radiographs of typical surgical indications in oral a maxillofacial surgery were analyzed by three different members of the workgroup, five times each. The measurements were analyzed with descriptive and comparative statistical methods. The mean coefficient of variation was 2.972% ± 2.361%. The measurements of defect regions were more consistent (2.252% ± 1.928%) than the measurements of surrounding bone (3.691% ± 2.626%). The analysis of variance did not show a statistically significant influence of the different raters to the measurements (ANOVA, Pr>F = 0.9462). Following the standard operation procedure this method seems to be an easy, cheap and close to practice way to visualize healing process of the jaws. Especially in the mandibula, but also in the maxilla with special reconsideration of the sinus-region, it seems to be suitable.
Cite this ArticleCrossMarkPublonsHarvard Library HOLLISGrowKudosResearchGateBase SearchOAI PMHAcademic MicrosoftScilitSemantic ScholarUniversite de ParisUW LibrariesSJSU King LibrarySJSU King LibraryNUS LibraryMcGillDET KGL BIBLiOTEKJCU DiscoveryUniversidad De LimaWorldCatVU on WorldCat

The incidence of hemodynamic and respiratory adverse events in morbidly obese presenting for Bariatric surgery

Published on: 25th July, 2018

OCLC Number/Unique Identifier: 7795943426

Context: Perioperative management of morbidly obese patients undergoing bariatric surgery is challenging. Lacking standardized perioperative protocols, complication rates may be high. This retrospective study aims to quantify the incidence of significant blood pressure decreases on induction of anesthesia and intraoperative hypoxemia, before implementation of a standardized protocol designed for bariatric surgery. Design: Retrospective, observational study. Setting: A 250-bed county hospital in northern Sweden. Subjects: 219 morbidly obese patients (body mass index > 35 kg/m2) who underwent bariatric surgery between 2003 and 2008. Main outcome measures: Incidence of systolic blood pressure (SAP) falls to less than 70% of the preoperative baseline during induction of anesthesia and incidence of perioperative hypoxemia. Results: The incidence of confirmed SAP falls to below 70% of baseline at induction of anesthesia was 56.2% (n = 123/219). This incidence rose with increasing age (p < 0.001) but not with body mass index (BMI). 3.7% (n = 8/219) of cases were marked as difficult intubations. A transient period of hypoxemia was observed in 6.8% (n = 15/219) and was more common with increasing BMI (p = 0.005). Fourteen different drug combinations were used in the study population. Of those administered an induction anesthetic drug, 72.6% (n = 159/193) were given an overdose when calculated by lean body weight, but this did not correlate significantly to SAP falls (p = 0.468). Conclusion: The incidence of a significant blood pressure fall upon induction of anesthesia was common. The incidence of airway and ventilation problems were low. Overdosing of anesthetics and excessive variation in applied anesthesia methods were found.
Cite this ArticleCrossMarkPublonsHarvard Library HOLLISGrowKudosResearchGateBase SearchOAI PMHAcademic MicrosoftScilitSemantic ScholarUniversite de ParisUW LibrariesSJSU King LibrarySJSU King LibraryNUS LibraryMcGillDET KGL BIBLiOTEKJCU DiscoveryUniversidad De LimaWorldCatVU on WorldCat

Enhancing adipose stem cell chondrogenesis: A study on the roles of dexamethasone, transforming growth factor β3 and ascorbate supplements and their combination

Published on: 31st July, 2017

OCLC Number/Unique Identifier: 7317597470

Varied exogenous chondrogenic factors (CFs) are implicated in promoting differentiation of stem cells along a chondrocyte lineage in the field of regenerative tissue engineering for articular cartilage repair. The effects of dexamethasone, transforming growth factor β3 (TGF-β3), ascorbate, and their combinations, on mRNA expression in micromass-cultured human adipose derived stem cells (hADSCs) were investigated as a function of time. Indices include chondrogenic, hypertrophic, angiogenic, fibrogenic and osteogenic markers along with mechanical properties, assessed by atomic force microscopy. Early in the culture, i.e., at day three, no significant differences in mRNA expression of SOX9, aggrecan, lubricin, Col XI, Col X, vascular endothelial growth factor, Col I, and alkaline phosphatase were observed among samples treated with different CFs. However, significant differences in mRNA expression levels of pre-mentioned markers among samples treated with each CF exist when samples were supplied with the CFs for more than three days. A new indexing scheme summing expression of chondrogenic and subtracting non-chondrogenic angiogenic, fibrogenic and osteogenic marker levels shows dexamethasone is the overall leading CF among the factors and their combinations. Based on this scheme, we have projected not only the possible signaling pathways which might be affected by addition of CFs but also hypothetical indexes that may occur upon temporal variation of growth factor regimens.
Cite this ArticleCrossMarkPublonsHarvard Library HOLLISGrowKudosResearchGateBase SearchOAI PMHAcademic MicrosoftScilitSemantic ScholarUniversite de ParisUW LibrariesSJSU King LibrarySJSU King LibraryNUS LibraryMcGillDET KGL BIBLiOTEKJCU DiscoveryUniversidad De LimaWorldCatVU on WorldCat

Adaptive planning and toxicities of uniform scanning proton therapy for lung cancer patients

Published on: 10th September, 2018

OCLC Number/Unique Identifier: 7869162666

Purpose: Adaptive planning is often needed in lung cancer proton therapy to account for geometrical variations, such as tumor shrinkage and other anatomical changes. The purpose of this study is to present our findings in adaptive radiotherapy for lung cancer using uniform scanning proton beams, including clinical workflow, adaptation strategies and considerations, and toxicities. Methods: We analyzed 165 lung patients treated using uniform scanning proton beams at our center. Quality assurance (QA) plans were generated after repeated computerized tomography (CT) scan to evaluate anatomic and dosimetric change during the course of treatment. Plan adaptation was determined mutually by physicists and physicians after QA plan evaluation, based on several clinical and practical considerations including potential clinical benefit and associated cost in plan adaption. Detailed analysis was performed for all patients with a plan adaptation, including the type of anatomy change, at which fraction the adaption was made, and the strategy for adaptation. Toxicities were compared between patients with and without plan adaptation. Results: In total, 32 adaptive plans were made for 31 patients out of 165 patients, with one patient undergoing adaptive planning twice. Anatomy changes leading to plan adaptation included tumor shrinkage (17), pleural effusion (3), patient weight loss (2), and tumor growth or other anatomy change (9). The plan adaptation occurred at the 15th fraction on average and ranged from the 1st to 31st fraction. Strategies of plan adaptation included range change only (18), re-planning with new patient-specific hardware (9), and others (5). Most toxicities were Grade 1 or 2, with dermatitis the highest toxicity rate. Conclusion: Adaptive planning is necessary in proton therapy to account for anatomy change and its effect on proton penetration depth during the course of treatment. It is important to take practical considerations into account and fully understand the limitations of plan adaptation process and tools to make wise decision on adaptive planning. USPT is a safe treatment for lung cancer patients with no Grade 4 toxicity.
Cite this ArticleCrossMarkPublonsHarvard Library HOLLISGrowKudosResearchGateBase SearchOAI PMHAcademic MicrosoftScilitSemantic ScholarUniversite de ParisUW LibrariesSJSU King LibrarySJSU King LibraryNUS LibraryMcGillDET KGL BIBLiOTEKJCU DiscoveryUniversidad De LimaWorldCatVU on WorldCat

Transcriptional profile of bovine preimplantation development selected based on G6PDH activity

Published on: 8th April, 2021

OCLC Number/Unique Identifier: 9026744769

The oocyte is the female gamete that contributes not only half of the genetic material but also all of the cytoplasm to the zygote, supplying the transcripts, proteins, mitochondria and other components necessary for early embryonic development. The intrinsic oocyte quality is one of the main factors affecting the embryo yield, the implantation rate and the rate of healthy offspring. It is obvious that a fertilized oocyte must reach the blastocyst stage within 6–9 days in the proper culture conditions to have a significant chance of inducing a pregnancy and producing an offspring. The ability to sustain the first week of embryonic development is clearly influenced by the follicular status from which the oocyte is obtained indicating that this developmental potential is inherent within certain oocytes. Since most early embryos that do not reach the blastocyst stage are blocked at or close to the maternal to zygotic transition (MZT)-stage, which occurs at the eight-cell stage in cattle, one could speculate that incompetent oocytes fail to appropriately activate the embryonic genome. Oocyte selection based on glucose-6-phosphate dehydrogenase (G6PDH) activity has been successfully used to differentiate between competent and incompetent bovine oocytes. Recently, molecular regulation of genes regulating biological process of Brilliant Cresyl Blue staining (BCB) selected oocytes and embryos was investigated to explain their variation in quality and developmental potentiality. This short review will highlights some of these efforts that have been done in this interesting area of research.
Cite this ArticleCrossMarkPublonsHarvard Library HOLLISGrowKudosResearchGateBase SearchOAI PMHAcademic MicrosoftScilitSemantic ScholarUniversite de ParisUW LibrariesSJSU King LibrarySJSU King LibraryNUS LibraryMcGillDET KGL BIBLiOTEKJCU DiscoveryUniversidad De LimaWorldCatVU on WorldCat

Atopic Conjunctivitis in Children: Influence of Treatment with Topical Cyclosporin 0.05% in the Quality of Life

Published on: 31st January, 2017

OCLC Number/Unique Identifier: 7317598595

Introduction: Forty-six per cent children have allergic rhinoconjunctivitis (Allergologica 2005). Working hypothesis: Ocular topical cyclosporine improves the quality of life for these patients. Material, methods, design: 2-year prospective study (2015-16), 40 patients with topical corticosteroids without improvement, followed 20 and 20 switched to corticosteroids cyclosporine 0.05%. Interview with Quality of Life Questionnaire in Children with rhinoconjunctivitis (PRQLQ) before and at the end of treatment. Mean age of 10.3 years with 60% male-40% female. Treatments were applied from January to March. There were 15 questions divided into two blocks. Children responded using a card with responses rated from zero (not bothered at all) to 6 (quite upset). Results: Before the 100% reported that, the itching was very bothersome. In the group of 40 children, 80% showed symptoms of epiphora and 60% showed symptoms of ocular inflammation. 100% complained of significant discomfort in rubbing their eyes, 30% did not like to take medications. Headaches affected 20%. 100% stated that they cannot play normally. 80% showed decreased concentration in class. Continuing with corticosteroids did not show statistically significant changes. Patients with cyclosporine improved the results by 3 points, with decreased itching, tearing, swelling, pain, eye rubbing, medication and headaches. In the 2nd questionnaire there was limited variation in the results related to fatigue, malaise, and irritability but with substantially improved balance of sleep, insomnia and concentration at school. Conclusion: Cyclosporine A is a cyclic polypeptide calcineurin inhibitor developed from the fungus Tolypocladium inflatum. The first dilution was 2% but it is currently used at a dilution of 0.05% and recent publications suggest nanosuspensions. Our study showed improvement in parameters related to symptoms, especially itching and lower improvement of psychological aspects, this achieves a better quality of life for children and more willingness to adhere to the treatment.
Cite this ArticleCrossMarkPublonsHarvard Library HOLLISGrowKudosResearchGateBase SearchOAI PMHAcademic MicrosoftScilitSemantic ScholarUniversite de ParisUW LibrariesSJSU King LibrarySJSU King LibraryNUS LibraryMcGillDET KGL BIBLiOTEKJCU DiscoveryUniversidad De LimaWorldCatVU on WorldCat

Investigation of radiation attenuation parameters of some drugs used in Chemotherapy in Wide Energy Region

Published on: 4th August, 2018

OCLC Number/Unique Identifier: 7844574123

Objectives: The aim of this study is to compute the radiation attenuation parameters such as mass attenuation coefficient, linear attenuation coefficient, half value layer, mean free path, and effective atomic number for some selected chemotherapy drugs such as Lomustine, Cisplatin, Carmustine, and Chlorambucil in the energy range from 1 keV to 100 GeV. Materials and Methods: The mass attenuation coefficients were calculated with the help of WinXCOM program. Using the obtained mass attenuation coefficients, other parameters such as linear attenuation coefficient, half value layer, mean free path, and effective atomic number were derived. Results: It is observed that the variations of these parameters with respect to the photon energy show changes in different energy regions. According to the obtained results, Cisplatin has the highest mass attenuation coefficient, linear attenuation coefficient and effective atomic number results among the selected chemotherapy drugs. Moreover, Chlorambucil has the highest half value layer and mean free path results among the selected chemotherapy drugs. Conclusion: The results of this study are useful for applied science fields such as radiation physics, pharmacology, and medical physics. These results may be useful when the selected chemotherapy drugs are used together with radiology.
Cite this ArticleCrossMarkPublonsHarvard Library HOLLISGrowKudosResearchGateBase SearchOAI PMHAcademic MicrosoftScilitSemantic ScholarUniversite de ParisUW LibrariesSJSU King LibrarySJSU King LibraryNUS LibraryMcGillDET KGL BIBLiOTEKJCU DiscoveryUniversidad De LimaWorldCatVU on WorldCat

Evaluation of unexplained clinical features of hepatic diseases through biopsies among hospitalized children: A cross-sectional study in Lahore, Pakistan

Published on: 11th September, 2018

OCLC Number/Unique Identifier: 7856177541

Objectives: There are variations in therapeutic regimens of different liver diseases. The accurate diagnosis ensures prompt recovery from these diseases. The present study aimed to evaluate the underlying causes of unexplained signs and symptoms associated with liver diseases through biopsies. Methods: A retrospective study was conducted in a public child care specialty of Lahore, Pakistan. The data was collected from medical records of the patients who were index hospitalized with unexplained clinical presentation of liver disease between 1st July, 2017 and 31st December, 2017. Data were analyzed by using Statistical Packages for Social Sciences (IBM SPSS Statistics for Windows, Version 21.0. Armonk, NY: IBM Corp.), and Microsoft Excel (MS Office 2010). Results: Overall, the records of 53 patients were selected for the study. Most of them were 11 to 15 years of age. The patients were presented with unexplained hepatomegaly (60.4%) and jaundice (40.7%) during index hospitalization which made them eligible for liver biopsy (LB). The findings of LB revealed that the underlying causes of liver diseases in most of the cases were metabolic (33.9%) and inflammatory disorders (22.6%). Majority of the patients were ≤4 years of age, however cryptogenic cirrhosis (39.1%) was commonly found in >10 years of age. Although most of the patients were suffering from metabolic disorders (p-value=0.07) and liver cirrhosis (p-value=0.08) but these were not statistically significant. Conclusions: LB was beneficial in evaluating the etiologies of unexplained signs and symptoms of liver diseases. It was found that glycogen storage diseases and liver cirrhosis were the most common etiologies of liver diseases among pediatric patients. But etiologies like metabolic and inflammatory diseases were insignificantly associated with gender.
Cite this ArticleCrossMarkPublonsHarvard Library HOLLISGrowKudosResearchGateBase SearchOAI PMHAcademic MicrosoftScilitSemantic ScholarUniversite de ParisUW LibrariesSJSU King LibrarySJSU King LibraryNUS LibraryMcGillDET KGL BIBLiOTEKJCU DiscoveryUniversidad De LimaWorldCatVU on WorldCat

Novel Complication of Nusinersen Treatment: Hyponatremia

Published on: 15th October, 2018

OCLC Number/Unique Identifier: 7905949311

There are variations in therapeutic regimens of different liver diseases. The accurate diagnosis ensNusinersen treatment is a novel therapy for spinal muscular atrophy (SMA) type 1; consequently, the adverse reactions of the therapy, have not been well known, yet. The present study is a case report that declares a hyponatremia development after the nursinersen therapy. Since the therapy is quite new one and has limited practice, we hope that this rare complication will contribute to the scientific literature.
Cite this ArticleCrossMarkPublonsHarvard Library HOLLISGrowKudosResearchGateBase SearchOAI PMHAcademic MicrosoftScilitSemantic ScholarUniversite de ParisUW LibrariesSJSU King LibrarySJSU King LibraryNUS LibraryMcGillDET KGL BIBLiOTEKJCU DiscoveryUniversidad De LimaWorldCatVU on WorldCat

CT signs of pressure induced expansion of paranasal sinus structures

Published on: 26th September, 2017

OCLC Number/Unique Identifier: 7317653929

Several articles have been written about hyper inflated sinus structures. Never before, however, a complete overview of all possible pressure induced variations of sinus anatomy have been published. The aim of this study was to make an inventory of the most common CT signs of hyper inflated paranasal sinus structures. During a period of 2 years all CT-scans of the paranasal sinuses made in an ENT-department were studied and the most typical shapes of hyper inflated sinus structures were recorded. The authors documented 9 different anomalies of the anterior paranasal sinus complex (frontal sinus, frontal and supra-orbital recess and anterior ethmoid), 8 of the ethmoid and 1 of the sphenoidal sinus. These hyper inflated paranasal sinus structures can only be generated by high positive intranasal pressures. The nose blowing manoeuvre is the only manoeuvre that generates extremely high pressures and as such it might be the driving force in the generation of these hyper inflated paranasal structures and consequently play a role in the pathophysiology of chronic sinusitis. Pneumatisation of the sinuses starts at birth and is a lifelong process. Sometimes, however, pneumatisation can be extreme and will result in facial deformities. Pneumosinus dilatans, is such a condition, characterized by an abnormal dilatation of a paranasal sinus cavity, containing air only. Most reports describe pneumosinus dilatans of the frontal sinus, but also other sinuses can show this phenomenon: maxillary sinus and in one case a unilateral pneumosinus dilatans of nearly all sinuses (maxillary, ethmoid, and sphenoid sinus) was described. Recently Kalavagunta et al., described a less dramatic expansion of the maxillary sinus and named it “Extensive Maxillary Sinus Pneumatisation” (EMSP). They were surprised to see that EMSP has received little attention in the literature. Neuner et al., described 9 different atypical pneumatisation abnormalities of the paranasal sinus anatomy. Most of deformities of the sinus pneumatisation are growth deformities of the thick bones that make up the frame of the sinuses. Only a few articles, deal with specific deformities of thinner bone structures such as “wavy orbital floor” and “frontal cells”. Never before, however, an article was published that studied all possible deformities due to increased pressures and tried to make a classification. So the aim of this study was to make an inventory of the most obvious pressures related deformities that can be seen on CT-scans of patients with rhinosinusitis.
Cite this ArticleCrossMarkPublonsHarvard Library HOLLISGrowKudosResearchGateBase SearchOAI PMHAcademic MicrosoftScilitSemantic ScholarUniversite de ParisUW LibrariesSJSU King LibrarySJSU King LibraryNUS LibraryMcGillDET KGL BIBLiOTEKJCU DiscoveryUniversidad De LimaWorldCatVU on WorldCat

Bifid Mandibular Canals: A case report and mini review

Published on: 3rd April, 2020

OCLC Number/Unique Identifier: 8875582681

he presence of bifid mandibu¬lar canals is an unusual but not rare occurrence. The mandibular canal containing the inferior alveolar artery, vein, and nerve, originates from the mandibular foramen and terminates at mental foramen [1-4]. In radiology, mandibular canal’s appearance has been described as “a radiolucent dark ribbon between two white lines”[5]. White and Pharoah defined it as “dark linear shadow with thin radiopaque superior and inferior borders cast by the lamella of bone that bounds the canal” [6]. Understanding of its anatomic variations is very important due to its clinical implications in various oral and maxillofacial treatments like removal of wisdom teeth [7], mandibular implant placement [8], in bilateral sagittal split osteotomy procedures and during fixation of mandibular fractures. Presence of bifid or multiple mandibular canals forces the clinician to change the treatment plan. Ignoring this variation can cause several complications intra or postoperatively or even result in failure of treatment. For instance a bifid canal if ignored during surgical removal of third molar or dental implant placement can cause prolonged pain even after administering local anesthesia and also severe bleeding if the accessory canal is encroached [2]. Bifid mandibular canals may originate from the mandibular foramen independently or might bifurcate from a single canal during its course inside the mandible [8]. Bifid mandibular canals have been by classified by multiple authors according to anatomical location and configuration, on panoramic radiographs and computerized tomography. According to Carter and Keen [1], inferior alveolar nerve can be arranged as- Type I: single large bony canal, Type II: canal is lower down in the mandible and Type III: canal separates posteriorly into two large branches. Nortje, et al. [9] gave patterns of duplication as- Type I: duplicate canals from a single mandibular foramen which can be of same size/ lower canal smaller/ upper canal smaller. Type II: short upper canal up to the second molar areas. Type III: two canals from separate foramina, joining at molar area and Type IV: supplemental canals joining the main canals in the retromolar areas. This report describes a case of a bilateral Bifid Mandibular Canal suspected by a panoramic radiograph and confirmed by a CBCT prior to a dental treatment.
Cite this ArticleCrossMarkPublonsHarvard Library HOLLISGrowKudosResearchGateBase SearchOAI PMHAcademic MicrosoftScilitSemantic ScholarUniversite de ParisUW LibrariesSJSU King LibrarySJSU King LibraryNUS LibraryMcGillDET KGL BIBLiOTEKJCU DiscoveryUniversidad De LimaWorldCatVU on WorldCat

Age Estimation Reports: Where do we stand?

Published on: 25th October, 2019

OCLC Number/Unique Identifier: 8299657336

Age estimations process is not standardized worldwide. However, there is a wide agreement about the most suitable methods currently available. Up until now, the procedure of creating expert reports and to implement quality assurance in age estimation are variable. Aim: The aim of this paper was to examine expert age estimation reports from around the world and identify the similarities and shortcomings present, which will help in providing recommendations to improve the reporting to reach standardization in expert age estimation reports. Methods and Material: A questionnaire was developed to explore whether there is a universal consensus in writing age estimation reports. Countries participated in the survey were: Afghanistan, Australia, France, Indonesia, Italy, New Zealand, Norway, Paraguay, Saudi Arabia, Spain, Switzerland, United Arab Emirates, United Kingdom, and the United States of America. Areas investigated by the survey included: Information about the individual in question and the entity requesting the assessment, if age interval is given along with if statistics were described in the report, if population reference data are used and reported and finally if the format of the report is standardized within each country. Results: The results of this survey suggest that there is a high degree of individual variation in age estimation reports, sometimes even within the same country. While the majority of participants report the main findings, some important information is still missing. The statistical information remains extremely varied. Conclusion: Although a resolution is not obvious, it is hoped that this study will promote further research and discussion on reporting age estimation. International guidelines on quality assurance in age estimation reports are urgently needed. Information to be reported should be specified on an international level and the exact report format to be used could be left to the national societies.
Cite this ArticleCrossMarkPublonsHarvard Library HOLLISGrowKudosResearchGateBase SearchOAI PMHAcademic MicrosoftScilitSemantic ScholarUniversite de ParisUW LibrariesSJSU King LibrarySJSU King LibraryNUS LibraryMcGillDET KGL BIBLiOTEKJCU DiscoveryUniversidad De LimaWorldCatVU on WorldCat
Help ?