Catheter

The revolution of cardiac surgery evolution Running head: Cardiac surgery evolution

Published on: 28th August, 2017

OCLC Number/Unique Identifier: 7317598809

From the first case of primitive cardiac surgery (CS), treatment of stab wound of the heart (Dr. Daniel Hale Williams, 1893), to recent surgical procedures and device implantations for end-stage heart failure (HF), the CS has grown and emerged in the public health more and more [1]. The heart valve disease had interested immediately since the non-cardiopulmonary era because of the multitude of rheumatic patients and congenital valve disease. In the 1952, Hufnagel implanted the first valve in descending aorta and it was the sign of the first step of the CS evolution. New prosthesis and heart valve techniques were tested between 1970 and 2000 with optimal results in patients’ quality of life and survival, at the same time of CPB evolution. Whilst, the evolution of heart valve surgery had stimulated new devices, prosthesis and the development of minimally invasive surgery, this was partially diminished by the spreading of trans catheter valve implantation. In the 2002, Dr. Alain Crabbier described a non-surgical prosthetic valve implantation firstly: it was the revolution of CS evolution [2]. The transcatheter valve implantation has evolved and spread rapidly with multiple approaches femoral to apical, aortic, axillary and carotid, and many suitable and technological devices. The higher and higher risk patients, the needs to avoid surgical complications, the evolution of available devices and the fabrication of new technologies have increased the efforts to improve trans catheter valve implantation [3]. The recent article of Loyalka et al, described a special case of tricuspid valve in valve replacement with Sapien 3, an innovative and alternative therapeutic choice to a tricuspid valve degeneration [4]. Instead, Sawara et al [5], documented as trans catheter aortic valve implantation for a failing surgical bio prosthesis or native aortic valve regurgitation has become an alternative for patients at high risk for redo surgical aortic valve replacement or aortic regurgitation since now off-label: that was a reliable and significant results in the era of trans catheter valve implantations. What would we attend from the future? In the most surgical centres, the trend were a significant decrease in patients undergoing to open-heart valve surgery compared to trans catheter valve implantation. Maybe the new ongoing studies of lower and mild-risk patients undergone to transcatheter procedure would open either a deeper collaboration of the heart team and a new therapeutic perspectives in the public health with a shift to more minimally invasive procedures, less day of hospitalization and I don’t see why not less costs for public health.
Cite this ArticleCrossMarkPublonsHarvard Library HOLLISGrowKudosResearchGateBase SearchOAI PMHAcademic MicrosoftScilitSemantic ScholarUniversite de ParisUW LibrariesSJSU King LibrarySJSU King LibraryNUS LibraryMcGillDET KGL BIBLiOTEKJCU DiscoveryUniversidad De LimaWorldCatVU on WorldCat

Brachial pseudoaneurysm associated with median nerve injury as a complication of peripherally inserted central catheter: A case report

Published on: 4th June, 2019

OCLC Number/Unique Identifier: 8165398303

Introduction: Peripherally inserted central venous catheters (PICCs) have been increasingly used as an alternative to conventional central venous catheters for long-term administration of chemotherapy, antibiotics, parenteral nutrition, and hydration in patients with difficult venous access. Traumatic complications to arteries and nerves adjacent to veins selected for PICC placement have been rarely described. Case presentation: We report the case of a PICC placement in the brachial vein of the right upper limb of a 78-year-old woman that resulted in brachial artery pseudoaneurysm and median nerve lesion. Discussion: The pseudoaneurysm was successfully repaired with thrombin injection, but neurological deficits to the hand resulting from nerve injury persisted even four months after the procedure.
Cite this ArticleCrossMarkPublonsHarvard Library HOLLISGrowKudosResearchGateBase SearchOAI PMHAcademic MicrosoftScilitSemantic ScholarUniversite de ParisUW LibrariesSJSU King LibrarySJSU King LibraryNUS LibraryMcGillDET KGL BIBLiOTEKJCU DiscoveryUniversidad De LimaWorldCatVU on WorldCat

Foley catheter balloon tamponade as a method of controlling iatrogenic pulmonary artery bleeding in redo thoracic surgery

Published on: 20th November, 2019

OCLC Number/Unique Identifier: 9269426092

Background: Pulmonary artery bleeding secondary to iatrogenic injury is a troublesome intraoperative complication. The likelihood of encountering this complication is significantly higher in redo surgery for a number of reasons, including distortion of anatomical structures, adhesions and loss of tissue planes. Significant blood loss, although rare, remains a concern, and can occasionally be life-threatening. When significant bleeding from the pulmonary artery occurs, it can be a challenging situation to manage. Case Report: A 65 year old female was undergoing redo thoracic surgery in the setting of a completion lobectomy for biopsy-proven primary adenocarcinoma of the lung. Iatrogenic injury to the pulmonary artery resulted in significant bleeding that could not be managed by gaining proximal control due to dense adhesions. The novel decision to utilize a Foley catheter for balloon tamponade was taken, in order to provide sufficient haemostasis for definitive surgical repair of the defect to be undertaken Conclusion: The increased technical difficulties of redo thoracic surgery are well recognised. We describe the first case of Foley catheter balloon tamponade being utilized in the context of iatrogenic pulmonary artery bleeding during thoracic surgery.
Cite this ArticleCrossMarkPublonsHarvard Library HOLLISGrowKudosResearchGateBase SearchOAI PMHAcademic MicrosoftScilitSemantic ScholarUniversite de ParisUW LibrariesSJSU King LibrarySJSU King LibraryNUS LibraryMcGillDET KGL BIBLiOTEKJCU DiscoveryUniversidad De LimaWorldCatVU on WorldCat

Transcatheter embolization of congenital vascular malformations, single center experience

Published on: 7th June, 2019

OCLC Number/Unique Identifier: 8165289153

Background: Congenital Vascular malformation relatively rare and extremely varied clinical presentations. The purpose of our study was to present our initial experience of embolization in a series of 26 patients with congenital vascular malformation to assess retrospectively the results and the complications of ethanol and coils embolization treatment of these patients. Methods: Retrospective trial, the study group consisted of 26 patients with congenital vascular malformations. Transcatheter arterial embolization by ethanol or coils were performed, Therapeutic outcomes were established by evaluating the clinical outcome of symptoms and signs, as well as the degree of devascularization at follow-up angiography. Results: Between November 2014 and March 2018, 26 consecutive patients (3 male, 23 female) at Alshifa Hospital - Cardiac Catheterization Center with congenital vascular malformations in the body and extremities underwent staged ethanol or coils embolization. The mean age of the patients was 25 years (age range, 6– 59 years). Ethanol embolization was administrated in 16 patients, coil embolization in 9 patients and graft stent in one patient. The side effect such as pain, pulsation, and bruit in most of the patients were obtained. The reduction of redness, swelling, and warmth was achieved in all of the patients, According to the angiographic findings, congenital vascular malformation were devascularized 100% in 12 patients, 50% to 99% in 11 patients, less than 50% in 3 patients. The most common complications were reversible skin necrosis. Conclusion: Transcatheter embolization by ethanol or coils has proved efficacious and safe in the treatment of congenital vascular malformation of the body and extremities but with acceptable risk of complications
Cite this ArticleCrossMarkPublonsHarvard Library HOLLISGrowKudosResearchGateBase SearchOAI PMHAcademic MicrosoftScilitSemantic ScholarUniversite de ParisUW LibrariesSJSU King LibrarySJSU King LibraryNUS LibraryMcGillDET KGL BIBLiOTEKJCU DiscoveryUniversidad De LimaWorldCatVU on WorldCat

Bleeding complications at the access sites during catheter directed thrombolysis for acute limb ischaemia: Mini review

Published on: 3rd March, 2021

OCLC Number/Unique Identifier: 8941332867

Acute and subacute ischemia of the lower limbs represents a major emergency with a high in-hospital mortality, complication, and leg amputation rates. Treatment options for acute limb ischemia include systemic anticoagulation, followed by various catheter based options including infusion of fibrinolytic agents (pharmacological thrombolysis), pharmacomechanical thrombolysis, catheter-mediated thrombus aspiration, mechanical thrombectomy, and any combination of the above or open surgical intervention (thromboembolectomy or surgical bypass). Minor and major bleeding complication during catheter directed thrombolysis (CDT) especially at access site are frequent. Bleeding complications require often an interruption or termination of CDT affecting clinical outcome of the patients. Recently we examined a new access site bleeding protection device during CDT.
Cite this ArticleCrossMarkPublonsHarvard Library HOLLISGrowKudosResearchGateBase SearchOAI PMHAcademic MicrosoftScilitSemantic ScholarUniversite de ParisUW LibrariesSJSU King LibrarySJSU King LibraryNUS LibraryMcGillDET KGL BIBLiOTEKJCU DiscoveryUniversidad De LimaWorldCatVU on WorldCat

Perceived causes and prevention of catheter-associated urinary tract infections among spinal cord injured patients

Published on: 27th November, 2019

OCLC Number/Unique Identifier: 9272371774

Catheter-associated urinary tract infection (CAUTI) is among the most common nosocomial infections especially in acute care settings. Its economic and unanticipated health implications make it burdensome for the healthcare providers and patients. The paper examined the perceived causes and mode of preventing urinary tract infections in patients with spinal cord injury. Qualitative research approach was utilized; the study site was a Tertiary Hospital in Nigeria. Eight (8) in-depth interviews (IDI) were conducted with healthcare providers managing patients with spinal cord injured in the hospital. The major risk factors causing urinary tract infection identified include financial problems, organization of care, human error, hospital environment and patient-related factors. To prevent urinary tract infections among patients in the hospital, a number of suggestions were made by the participants such as training of caregivers and educating patients and relations. The authors concluded that the incidence of CAUTI could be reduced in the hospital if the opinions of stakeholders are fairly considered.
Cite this ArticleCrossMarkPublonsHarvard Library HOLLISGrowKudosResearchGateBase SearchOAI PMHAcademic MicrosoftScilitSemantic ScholarUniversite de ParisUW LibrariesSJSU King LibrarySJSU King LibraryNUS LibraryMcGillDET KGL BIBLiOTEKJCU DiscoveryUniversidad De LimaWorldCatVU on WorldCat

Persistent hydronephrosis after pyeloplasty: Is it a true obstruction? The role of endourology

Published on: 13th April, 2020

OCLC Number/Unique Identifier: 8582316817

Introduction: Anderson-Hynes pyeloplasty remains the gold standard in the treatment of ureteropelvic junction obstruction. The diagnostic criteria for defining the failure of pyeloplasty are not well-defined or even arbitrary. Likewise, the ideal treatment of persistent hydronephrosis after pyeloplasty is not well established. We tested an innovative endourological procedure, which simultaneously allows a diagnostic definition of failure and treatment when necessary. Materials and methods: The endourological procedure was applied prospectively to 13 cases from 2006 to 2015. The mean hydronephrosis was 3 cm and all the patients showed an obstructive pattern at scintigraphie. Of these, only 2 patients had symptoms. The procedure consisted in the endoscopic calibration of the pyeloureteral junction. In case of confirmed persistent stenosis, the procedure continued with the high pressure dilation of the junction. The calibration/dilation procedure was carried out with a balloon catheter, previously used for high pressure dilation in the obstructive megaureter. In all patients, a ureteral stent was positioned for 6 - 8 weeks. The patients were then followed up using ultrasound and renoscintigraphie. Results: According to the endoscopic balloon procedure, anastomosic stenosis was confirmed in 3 cases, treated with high pressure dilation during the same procedure. In 10 cases no stenosis was found and we followed-up these patients with periodic ultrasound and scintigraphie. Conclusion: The calibration/dilation of the pyeloureteral junction represents in our opinion a useful diagnostic and therapeutic tool that allows to limit the repetition of open surgery only to symptomatic cases and those non-responders to endoscopic treatment.
Cite this ArticleCrossMarkPublonsHarvard Library HOLLISGrowKudosResearchGateBase SearchOAI PMHAcademic MicrosoftScilitSemantic ScholarUniversite de ParisUW LibrariesSJSU King LibrarySJSU King LibraryNUS LibraryMcGillDET KGL BIBLiOTEKJCU DiscoveryUniversidad De LimaWorldCatVU on WorldCat

Percutaneous treatment of severe retroperitoneal hematoma after percutaneous coronary intervention

Published on: 25th September, 2021

OCLC Number/Unique Identifier: 9272370670

We describe a patient who developed severe retroperitoneal and intraperitoneal bleeding complicating femoral arterial catheterization for Percutaneous coronary intervention. Balloon tamponade of the actively bleeding femoral artery was effective in sealing off the leakage.This management strategy for this problem emphasizing an anatomical based interventional approach if the patient does not stabilize with volume resuscitation.
Cite this ArticleCrossMarkPublonsHarvard Library HOLLISGrowKudosResearchGateBase SearchOAI PMHAcademic MicrosoftScilitSemantic ScholarUniversite de ParisUW LibrariesSJSU King LibrarySJSU King LibraryNUS LibraryMcGillDET KGL BIBLiOTEKJCU DiscoveryUniversidad De LimaWorldCatVU on WorldCat

Stiff “Left Atrial” syndrome post-mustard procedure

Published on: 1st December, 2021

OCLC Number/Unique Identifier: 9359567131

Objectives: We describe the clinical course and management of two patients with post-capillary pulmonary hypertension due to diffuse pulmonary venous baffle calcification decades post-Mustard procedure.Background: From the late 1950s to the early 1990s, the definitive surgical repair for children with D-transposition of the great vessels (D-TGA) was an atrial switch procedure (either Senning or Mustard operation) which utilizes atrial-level baffles to shunt pulmonary venous blood to the morphologic right (systemic) ventricle and caval blood to the morphologic left (sub-pulmonary) ventricle. From a hemodynamic standpoint, baffle leaks and stenoses as well as precapillary pulmonary hypertension have all been described as both early and late complications [1]. Recently, delayed post-capillary pulmonary hypertension (in the absence of discrete baffle obstruction) decades post-atrial switch has also been described [2]. The underlying pathophysiology for this postcapillary pulmonary hypertension is unclear but is theorized to involve impaired diastology referable to the pulmonary venous baffle. Methods/Results: Using hemodynamic and imaging data, we describe two patients with extensive pulmonary venous baffle calcification and resultant pulmonary hypertension from the so-called “stiff left atrial (LA) syndrome.” This problem can be difficult to treat medically and is not amenable to catheter-based interventions. We hypothesize that this is an underlying mechanism for pulmonary hypertension in at least some post-Mustard and Senning patients. Conclusion: We describe the treatments and clinical course for each of these patients, and in particular describe how the surgical revision of the pulmonary venous baffle in one case led to the complete resolution of symptoms.
Cite this ArticleCrossMarkPublonsHarvard Library HOLLISGrowKudosResearchGateBase SearchOAI PMHAcademic MicrosoftScilitSemantic ScholarUniversite de ParisUW LibrariesSJSU King LibrarySJSU King LibraryNUS LibraryMcGillDET KGL BIBLiOTEKJCU DiscoveryUniversidad De LimaWorldCatVU on WorldCat

The identification of the true nature of pseudofungus structures as polyurethane catheter fragments

Published on: 4th January, 2022

OCLC Number/Unique Identifier: 9396195229

Pseudofungus structures in lymph node tissues have been reported on multiple occasions. Despite a variety of investigative tests including histochemical special stains and energy dispersive spectral analysis, the underlying nature and origin of these pseudofungus structures has never been clearly defined. The most common hypothesis suggests that they represent collagen fibers that become coated with iron and calcium. Herein, evidence is given that the pseudofungus structures identified in the lymph node tissues represent fragments of polyurethane catheters. The evidence includes both a comparison of these pseudofungus structures to fragments of polyurethane well documented in the literature and a comparison of polyurethane catheter scrapings to the pseudofungus structures identified in the literature. In both of these comparisons, the morphology of the polyurethane fragments are identical to the pseudofungus structures. This is the first definitive report identifying polyurethane catheter fragments as representing the true nature and etiology of pseudofungus structures in lymph node tissues.
Cite this ArticleCrossMarkPublonsHarvard Library HOLLISGrowKudosResearchGateBase SearchOAI PMHAcademic MicrosoftScilitSemantic ScholarUniversite de ParisUW LibrariesSJSU King LibrarySJSU King LibraryNUS LibraryMcGillDET KGL BIBLiOTEKJCU DiscoveryUniversidad De LimaWorldCatVU on WorldCat

Comparision of intra cervical PGE2 gel and transcervical Foley’s catheter for pre-induction cervical ripening

Published on: 3rd May, 2022

OCLC Number/Unique Identifier: 9497124492

Introduction: Induction of labour is a common obstetric intervention, occurring in approximately 25% of term pregnancies in developing countries. Pharmacological and mechanical methods commonly used are prostaglandin preparations (PGE1 and PGE2) and various intracervical catheters (single or double balloon), respectively.Material and methods: Study was conducted in Siliguri District Hospital, Siliguri, Darjeeling, west Bengal. 100 antenatal woman admitted in obstetrics ward with pog more than 37 weeks were taken for study after applying inclusion and exclusion criteria. 50 were induced with cerviprime gel and 50 with intracervical foley catheter. Statistical analysis done.Results: Mean interval between treatment initiation and delivery was not statistically significant, tachysystole was more common in group B women, rate of LSCS and NVD was similar in both groups.Conclusion: It can be concluded from the present study that Foley’s catheter (mechanical) and prostaglandin E2 gel [pharmacological] both are effective agents for preinduction cervical ripening which substantially improve the bishops score and increase the chances of successful labour induction. There is no significant difference in their efficacy, mode of delivery and perinatal outcome.
Cite this ArticleCrossMarkPublonsHarvard Library HOLLISGrowKudosResearchGateBase SearchOAI PMHAcademic MicrosoftScilitSemantic ScholarUniversite de ParisUW LibrariesSJSU King LibrarySJSU King LibraryNUS LibraryMcGillDET KGL BIBLiOTEKJCU DiscoveryUniversidad De LimaWorldCatVU on WorldCat

A Wolff-Parkinson-White (WPW) Electrocardiographic Pattern in Asymptomatic Patient – State-of-the-Art-Review

Published on: 7th June, 2022

A comprehensive approach to asymptomatic adults with Wolff-Parkinson-White (WPW) pattern discovered incidentally on routine electrocardiography (ECG) is debatable. The objective of this review article is to update the most recent evidence on the management of young patients with asymptomatic WPW patterns. A substantial proportion of adults with WPW patterns on ECG may remain asymptomatic but the lifetime risk for fatal arrhythmias still exists. The inherent properties of the accessory pathway determine the risk of sudden cardiac death. A low-risk pathway is considered when the pre-excitation is intermittent on ambulatory monitoring or when it disappears completely or abruptly during exercise testing. On the other hand, a high-risk pathway in EP study is suggested by the presence of the shortest pre-excited RR interval (SPERRI) during atrial fibrillation of ≤ 250 ms or accessory pathway effective refractory period (APERP) ≤ 240 ms. The cardiac evaluation may thus be considered in asymptomatic patients with WPW to determine the individual risk for future symptomatic arrhythmia. A shared-decision making must be performed before offering catheter ablation whose procedural success rate is high.
Cite this ArticleCrossMarkPublonsHarvard Library HOLLISGrowKudosResearchGateBase SearchOAI PMHAcademic MicrosoftScilitSemantic ScholarUniversite de ParisUW LibrariesSJSU King LibrarySJSU King LibraryNUS LibraryMcGillDET KGL BIBLiOTEKJCU DiscoveryUniversidad De LimaWorldCatVU on WorldCat

Accidental placement of hemodialysis catheter tip in the right internal mammary vein: a case report

Published on: 5th October, 2022

OCLC Number/Unique Identifier: 9645193845

Hemodialysis catheter placement, particularly Internal Jugular Catheter insertion, is a very common procedure for patients who require urgent access to renal replacement therapy. Most of these procedures are done under ultrasound guidance as recommended by KDIGO 2019 vascular access guidelines. However, catheter tip misplacement can still occur even in the experts’ hands and despite the use of ultrasound. In this case report, we will discuss a hemodialysis catheter tip placement in the right internal mammary vein and how we managed it.
Cite this ArticleCrossMarkPublonsHarvard Library HOLLISGrowKudosResearchGateBase SearchOAI PMHAcademic MicrosoftScilitSemantic ScholarUniversite de ParisUW LibrariesSJSU King LibrarySJSU King LibraryNUS LibraryMcGillDET KGL BIBLiOTEKJCU DiscoveryUniversidad De LimaWorldCatVU on WorldCat

Chronic thromboembolic pulmonary hypertension resulting in decompensated right heart failure

Published on: 24th November, 2022

Chronic thromboembolic pulmonary hypertension is a notoriously underdiagnosed cause of severe pulmonary hypertension. It is a form of precapillary pulmonary hypertension (PH) that results from intraluminal thrombus organization and fibrous formation which ultimately results in the complete obliteration of pulmonary arteries, resulting in increased pulmonary vascular resistance which leads to the development of pulmonary hypertension and as a result right heart failure. The mechanism involves the narrowing of the pulmonary artery which increases blood pressure within the lungs and impairs blood flow which increases the workload of the right side of the heart ultimately causing right heart failure. Pulmonary hypertension can also cause arrhythmias, blood clots, and bleeding in the lungs. Even though CTEPH is a deadly condition, among all forms of pulmonary hypertension, CTEPH is the only curable form. Echocardiography is the initial assessment tool for suspected PH. A right heart catheterization may be performed to confirm the presence of pulmonary hypertension. Confirmation of CTEPH requires a V/Q scan. Although ventilation/perfusion scintigraphy has a major role in the evaluation of patients with suspected CTEPH, nowadays CTA chest is being used widely as it produces much better-quality images compared to V/Q scan. Without treatment, the prognosis is very poor. Out of three treatment modalities such as; pulmonary endarterectomy (PEA) surgery, balloon pulmonary angioplasty (BPA), and medical therapy, surgery is the gold standard. The physician must be familiar with the disease entity, early diagnosis, and appropriate treatment to improve survival. Here we present a literature review on this topic.
Cite this ArticleCrossMarkPublonsHarvard Library HOLLISGrowKudosResearchGateBase SearchOAI PMHAcademic MicrosoftScilitSemantic ScholarUniversite de ParisUW LibrariesSJSU King LibrarySJSU King LibraryNUS LibraryMcGillDET KGL BIBLiOTEKJCU DiscoveryUniversidad De LimaWorldCatVU on WorldCat

How to manage balloon entrapment during percutaneous coronary intervention of a calcified lesion “Case report”

Published on: 2nd December, 2022

Percutaneous coronary angioplasty is a minimally invasive procedure aimed at unclogging a coronary artery with a low complication rate (with a serious complication rate of 3% to 7% and a mortality rate of 1.2%). Device entrapment during PCI is a rare but life-threatening complication that occurs in < 1% of PCIs and balloon entrapment comes second after coronary guidewires. We present the case of 68-years-old man, smoker, hypertensive and type2 diabetic that presents angina with evidence of ischemia on myocardial tomoscintigraphy and in whom the radial coronary angiography reveals a tight calcified mid LAD stenosis. During his PCI and after dilatation with an NC balloon 2.5 × 12 the latter refuses to deflate and remains trapped in the lesion with the appearance of pain and ST-elevation despite several attempts to dilute the product in the inflator and to burst it by overexpansion. Traction on the balloon resulted in the deep intubation of the guiding-catheter, which comes in contact with the trapped balloon, and the rupture of the latter’s hypotube, which remains inflated at the site of the lesion and mounted on the 0.014 guidewire. We put a second 0.014 guidewire distally in the LAD and twisted with the distal part of the first guidewire, then we introduced a second balloon 2.0 × 20 over the second guidewire until the distal part of the guiding-catheter and inflated to trap the stucked balloon. We gradually removed this emergency assembly that allowed us to retrieve the trapped balloon. The control injection revealed a thrombotic occlusion of the LAD treated by thrombectomy and anti-GPIIbIIIa followed by a DES 2.75 × 28 placement. The patient was discharged 48 hours later with a good LVEF. The possible balloon entrapment mechanisms are an acute recoil of a highly calcified lesion with compression of the incompletely deflated balloon, which seems to be the case in our patient, strangulation of the proximal balloon end by the guiding-catheter if the balloon is removed before complete deflation and break or bend of the hypotube. The solutions in case of undeflatable balloon entrapment are to dilute the product in the inflator, to burst it by overexpansion, to pierce it through a stiff guidewire (or through its other end on a Microcatheter or OTW balloon), to cut its outer part and let it empty passively, to introduce a second guide-wire and perform a Buddy-Balloon or to transfer the patient to Surgery. Material entrapment remains a rare but life-threatening complication, its eviction requires the choice of material size and gentle manipulations (small balloons in the event of a calcified lesion) and its management uses different techniques, the choice of which depends on the clinical and anatomical situation. 
Cite this ArticleCrossMarkPublonsHarvard Library HOLLISGrowKudosResearchGateBase SearchOAI PMHAcademic MicrosoftScilitSemantic ScholarUniversite de ParisUW LibrariesSJSU King LibrarySJSU King LibraryNUS LibraryMcGillDET KGL BIBLiOTEKJCU DiscoveryUniversidad De LimaWorldCatVU on WorldCat

A rare case of foreign body in coronary sinus. A novel endovascular method for retrieval

Published on: 30th March, 2023

Central venous catheter fracture and migration are rare complications in patients receiving long-term infusions or chemotherapy. We present a rare case of a chest port catheter fracture that migrated into the coronary sinus. This case is likely the fourth report of a port catheter fracture with migration to the coronary sinus. Because of the difficult-to-retrieve location, multiple attempts were unsuccessful with traditional techniques using a loop snare. Finally, the fractured portion was disengaged from the coronary sinus using a navigational electrophysiology catheter guided by intracardiac echocardiography; the dislodged end was snared and eventually removed by the femoral route. This case of a chest port catheter fracture is unique because of the unusual migration to the coronary sinus and the use of a navigational electrophysiology catheter as a novel retrieval technique.
Cite this ArticleCrossMarkPublonsHarvard Library HOLLISGrowKudosResearchGateBase SearchOAI PMHAcademic MicrosoftScilitSemantic ScholarUniversite de ParisUW LibrariesSJSU King LibrarySJSU King LibraryNUS LibraryMcGillDET KGL BIBLiOTEKJCU DiscoveryUniversidad De LimaWorldCatVU on WorldCat

Evaluation of catheter related bacteremia in patients with end stage renal disease on hemodialysis

Published on: 25th April, 2023

Infections are common complications among patients on chronic hemodialysis. Hemodialysis patients with a catheter have a 2- to 3-fold increased risk of hospitalization for infection and death compared with patients with an arteriovenous fistula or graft [1]. 
Cite this ArticleCrossMarkPublonsHarvard Library HOLLISGrowKudosResearchGateBase SearchOAI PMHAcademic MicrosoftScilitSemantic ScholarUniversite de ParisUW LibrariesSJSU King LibrarySJSU King LibraryNUS LibraryMcGillDET KGL BIBLiOTEKJCU DiscoveryUniversidad De LimaWorldCatVU on WorldCat

Early Outcomes of a Next-Generation Balloon-Expandable Transcatheter Heart Valve - The Myval System: A Single-Center Experience From Serbia

Published on: 26th June, 2023

Transcatheter aortic valve implantation (TAVI) is one of the most effective treatments for severe aortic valve stenosis (AVS). Different genres and generations of transcatheter heart valves (THVs) are accessible, offering operators an opportunity to choose a patient-tailored device. In this single-center study, we present the outcomes of Serbian patients treated with next-generation Myval THV for severe symptomatic AVS. Myval THV was implanted in all consecutive patients who underwent TAVI at the Dedinje Cardiovascular Institute of Belgrade, Serbia between October 2020 and September 2021. The primary endpoint was device success on day 30. Secondary endpoints included 30-day all-cause mortality, cardiovascular death, stroke, moderate/severe paravalvular leak (PVL), and new permanent pacemaker implantation (PPI). TAVI was performed as per the European Society of Cardiology guidelines. The study comprised thirteen patients, aged 72±13 years with mean EuroSCORE (7.17%) and Society of Thoracic Surgeons (2.72%,) scores who underwent TAVI successfully with 92.3% using the percutaneous approach. Myval THV intermediate and extra-large sizes were implanted in 46% and 15% of patients, respectively. This acute procedure success rate was 100%. The primary composite endpoint of early device success was achieved in all patients. None of the patients had clinically significant aortic regurgitation or moderate/severe PVL. No patient experienced stroke, contrast-induced acute kidney injury, device-related vascular complications, or a new PPI. The all-cause mortality rate at 30 days was 0%. Myval THV system demonstrated a favorable safety/efficacy profile within 30 days post-procedure at a single center in Serbia. This is the first report of my experience with Myval THV from Serbia.
Cite this ArticleCrossMarkPublonsHarvard Library HOLLISGrowKudosResearchGateBase SearchOAI PMHAcademic MicrosoftScilitSemantic ScholarUniversite de ParisUW LibrariesSJSU King LibrarySJSU King LibraryNUS LibraryMcGillDET KGL BIBLiOTEKJCU DiscoveryUniversidad De LimaWorldCatVU on WorldCat

Transcatheter Aortic Valve Implantation in Two High-Risk Patients with Low Coronary Ostial Heights Using the Novel Balloon-Expandable Myval Valve

Published on: 1st August, 2023

The treatment of severe aortic stenosis by transcatheter aortic valve implantation (TAVI) is challenging in patients with high-risk coronary anatomy that is predisposed to iatrogenic or delayed coronary obstruction. Hence, the evidence on performing TAVI with adequate coronary protection with or without deploying a stent needs to be accumulated. We report two cases of TAVI performed in patients with low coronary heights, wherein a “wire only” strategy was used to provide coronary protection along with the implantation of a novel balloon-expandable Myval THV. The first patient underwent a valve-in-valve TAVI, while the second patient underwent the replacement of a native bicuspid Type 1A valve. This case series presents two high-risk TAVI cases wherein a guide extension catheter and a supportive coronary guidewire provided sufficient coronary protection. None of the cases required any rescue revascularization and no incidences of a new pacemaker implantation were reported.
Cite this ArticleCrossMarkPublonsHarvard Library HOLLISGrowKudosResearchGateBase SearchOAI PMHAcademic MicrosoftScilitSemantic ScholarUniversite de ParisUW LibrariesSJSU King LibrarySJSU King LibraryNUS LibraryMcGillDET KGL BIBLiOTEKJCU DiscoveryUniversidad De LimaWorldCatVU on WorldCat

CT-guided Retrograde Urography as a Diagnostic Tool for Post-kidney Transplantation Evaluation: A Case Report

Published on: 4th September, 2023

The vast majority of urological complications occur at the ureterovesical junction and usually occur early after transplantation. The aim of this study is to enhance the quality of medical care provided to patients who undergo kidney transplantation. Cystography was conducted on renal transplant recipients utilizing computed tomography. The utilization of changes in the patient’s position and reconstructed images of the bladder can serve as a diagnostic tool to assess the normal functioning of the urinary tract system subsequent to kidney transplantation. To ensure adequate filling of the bladder and ureter, it is necessary to introduce varying amounts of contrast medium through the urinary catheter into these structures. This diagnostic procedure aims to verify the existence of stenosis or leakage occurring at the vesicoureteral junction. The evaluation and diagnosis of urinary tract problems subsequent to kidney transplantation can be effectively conducted. Furthermore, it has the potential to mitigate the adverse effects and alleviate the strain on the renal system resulting from the administration of contrast agents in computed tomography urography. CT-guided cystography can enhance the medical quality and comfort of Kidney transplantation patients.
Cite this ArticleCrossMarkPublonsHarvard Library HOLLISGrowKudosResearchGateBase SearchOAI PMHAcademic MicrosoftScilitSemantic ScholarUniversite de ParisUW LibrariesSJSU King LibrarySJSU King LibraryNUS LibraryMcGillDET KGL BIBLiOTEKJCU DiscoveryUniversidad De LimaWorldCatVU on WorldCat
Help ?