Articles

Patients’ satisfaction and associated factors towards nursing care in Dessie Referral Hospital, Northeast Ethiopia

Published on: 29th November, 2019

OCLC Number/Unique Identifier: 8875583474

Introduction: A patient satisfaction is considered as one of the desire outcomes of health care and it is directly related with utilization of health services. However, its level is falls at the fundamental level in developing countries including Ethiopia. Objective: To assess the level of patients’ satisfaction and its associated factors at Dessie Referral Hospital, Northeast Ethiopia Methods and Materials: An institutional based cross-sectional study design was employed from May 1 to June 1 2019. A total of 374 patients were selected by using systematic sampling technique and interviewer administer structured questionnaire was used to collect data. After data collection, the data were checked for its completeness and entered into Epi data version 3.1. The data were presented in frequency distribution tables and graphs. Both bivariable and multivariable logistic regression were applied to identify factors at a p < 0.05. Result: Among total study participants, 220 (58.8%) patients were satisfied with nursing care service. Patients who had particular nurse for nursing care were more likely satisfied than those who didn’t have particular nurse for nursing care (AOR = 2.01, 95% CI: 1.212 - 3.334). Patients who had other diseases in addition to current health problem were more likely satisfied (AOR = 0.45 & 95% CI: 0.196 - 1.031) compared with patients who had not. Conclusion: In this finding, the level of patients’ satisfaction towards nursing care was low. Having specific or particular nurse and presence of comorbid disease were factors associated with patients’ satisfaction towards nursing care. Health institutions should assign particular nurses for patients to improve their satisfaction and quality of care. In addition, nurses should give great attention to their patients who have co-morbid illnesses.
Cite this ArticleCrossMarkPublonsHarvard Library HOLLISGrowKudosResearchGateBase SearchOAI PMHAcademic MicrosoftScilitSemantic ScholarUniversite de ParisUW LibrariesSJSU King LibrarySJSU King LibraryNUS LibraryMcGillDET KGL BIBLiOTEKJCU DiscoveryUniversidad De LimaWorldCatVU on WorldCat

Detection limit of a lutetium based non-paralizable PET-like detector

Published on: 16th April, 2020

OCLC Number/Unique Identifier: 8586063433

The effect of the intrinsic lutetium radioactivity on the detection performances of a LYSO based in-beam PET-like prototype used for quality control of hadrontherapy treatments is studied. This radioactivity leads to a background that degrades the measurement of the β+ signal. In particular, it prevents the measurement of faint signals originating from low activity β+ sources. This paper presents a method to estimate the minimum β+ activity that can be measured for any acquisition time taking into account the non-extensible dead time of the detector. This method is illustrated with experimental data collected with the in-beam PET-like prototype. The results presented in this paper are therefore specific to this detector. The method can however be applied in other contexts, either to other lutetium based PET detectors or even to non-PET detectors affected by lutetium radioactivity. The dead time correction formalism can also be used generally to scale signal and background yields in any non-paralizable detector, even those in which the background is not due to the presence of intrinsic radioactivity.
Cite this ArticleCrossMarkPublonsHarvard Library HOLLISGrowKudosResearchGateBase SearchOAI PMHAcademic MicrosoftScilitSemantic ScholarUniversite de ParisUW LibrariesSJSU King LibrarySJSU King LibraryNUS LibraryMcGillDET KGL BIBLiOTEKJCU DiscoveryUniversidad De LimaWorldCatVU on WorldCat

Evaluation of Uranium in Organs of Residents from an Uranium-Rich Region using Teeth as Bioindicators

Published on: 26th March, 2020

OCLC Number/Unique Identifier: 8588716918

The Uranium extraction and processing plant of INB (Brazilian Nuclear Industries) is in Caetité, a city located in a region hosting the largest Uranium reserve of the country. The degree of Uranium contamination in the Caetité population was investigated before using teeth as bioindicator, where a quite high Uranium concentration was measured in this region, about 160 times higher than the world-wide average. Radiobiological risks are here evaluated from Uranium burdens in organs as skeleton, kidneys, liver, tissues and blood, which were estimated from transfer coefficients and effective internal doses. This was accomplished by means of calculations with the use of the STATFLUX/ICRP approach, plus a set of Uranium transfer rate parameters as function of individual’s age assuming an uninterrupted exposure over a period of 60 years. It was found that U ingestion rates by residents of Caetité are three orders of magnitude higher than worldwide average, indicating that food and water would exhibit high levels of contamination. Calculated effective internal doses range from a minimum of one to a maximum of three orders of magnitude higher than background doses, for blood and bones respectively. The likelihood that this circumstance could lead to serious health problems as e.g. neoplasia is addressed. The methodology presented in this work offers subsidies for further studies on environmental pollution by radionuclides.
Cite this ArticleCrossMarkPublonsHarvard Library HOLLISGrowKudosResearchGateBase SearchOAI PMHAcademic MicrosoftScilitSemantic ScholarUniversite de ParisUW LibrariesSJSU King LibrarySJSU King LibraryNUS LibraryMcGillDET KGL BIBLiOTEKJCU DiscoveryUniversidad De LimaWorldCatVU on WorldCat

States Care - The Cure for Patient Healthcare

Published on: 12th November, 2019

Clinical physicians believe they are drowning . . . because they are! Between complying with an ever-changing landscape of time-wasting federal regulations, avoiding Health Insurance Portability and Accountability Act violations, plus the entire billing process, who can keep up with the literature, study a patient’s medical history, or even talk with a patient?!? 
Cite this ArticleCrossMarkPublonsHarvard Library HOLLISGrowKudosResearchGateBase SearchOAI PMHAcademic MicrosoftScilitSemantic ScholarUniversite de ParisUW LibrariesSJSU King LibrarySJSU King LibraryNUS LibraryMcGillDET KGL BIBLiOTEKJCU DiscoveryUniversidad De LimaWorldCatVU on WorldCat

The effects of a clinical ladder program on professional development and job satisfaction of acute care nurses

Published on: 26th July, 2019

OCLC Number/Unique Identifier: 8207891872

Nurses play a vital role in acute care hospitals and health care delivery. The purpose of this research study is to identify the nurse’s perception of the Clinical Ladder Program at their hospital and the correlation it has on the nurse’s job satisfaction and their professional development. A quantitative study will be conducted using two convenience samples from Alexian Brothers Hospital and Saint Anthony’s hospital with a total of 52 nurses who are currently participating in the clinical ladder program.
Cite this ArticleCrossMarkPublonsHarvard Library HOLLISGrowKudosResearchGateBase SearchOAI PMHAcademic MicrosoftScilitSemantic ScholarUniversite de ParisUW LibrariesSJSU King LibrarySJSU King LibraryNUS LibraryMcGillDET KGL BIBLiOTEKJCU DiscoveryUniversidad De LimaWorldCatVU on WorldCat

Comparison of muscle activation of 3 different hip belt squat techniques

Published on: 15th September, 2020

OCLC Number/Unique Identifier: 8669246407

The purpose of this study was to differentiate between muscular activity of three different types of belt squats (SquatMax-MD, Pit Shark and Monster Rhino) and the muscle activation of the rectus femoris, vastus medialis oblique, gluteus maximus, and gluteus medius. Fourteen healthy, male athletes, over the age of 18 years, performed 2 sets of 5 repetitions on each of the three belt squat machines with a weight equivalent to each participant’s body weight. Athletes were given at least 2 minutes of rest between each set and condition. Electromyographic data were collected from four muscles: rectus femoris, vastus medialis oblique, gluteus maximus, and gluteus medius muscles. ANOVA revealed the SquatMax-MD belt squat resulted in the highest muscle activation in every muscle, with significantly higher activity in the rectus femoris, vastus medialis oblique, and gluteus medius muscles. The Monster Rhino belt squat produced the second highest muscle activation with the Pit Shark belt squat creating the lowest muscle activation. In totality, the SquatMax-MD produced 38.7% greater muscle activation than the Monster Rhino and 12.2% greater activation than the Pit Shark. The belt squat can be an advantageous exercise because it can effectively load the lower body while de-loading the spine and upper body. The difference in activation between the SquatMax-MD and other belt squats may be due, in part, to the design of the machines. The additional activation produced by the SquatMax-MD belt squat may be useful for individuals seeking hypertrophy, strength, or a reduction in injury risk.
Cite this ArticleCrossMarkPublonsHarvard Library HOLLISGrowKudosResearchGateBase SearchOAI PMHAcademic MicrosoftScilitSemantic ScholarUniversite de ParisUW LibrariesSJSU King LibrarySJSU King LibraryNUS LibraryMcGillDET KGL BIBLiOTEKJCU DiscoveryUniversidad De LimaWorldCatVU on WorldCat

A quantum mechanical model for hole transport through DNA: predicting conditions for oscillatory/non-oscillatory behavior

Published on: 9th March, 2020

OCLC Number/Unique Identifier: 8558600875

A quantum mechanical model that considers tunneling and inelastic scattering has been applied to explain the hole transfer reaction from a G (Guanine) base to a GGG base cluster through a barrier of Adenine bases, (A)n (n = 1-16). For n = 1, the ratio of tunneling to inelastic scattering is about 6, which is sharply decreased to around 0.23 and 5.23 × 10-8 for n = 4 and 16 respectively, suggesting dominance of inelastic scattering for n ≥ 4. As in experiment, the calculated product yield ratios (PGGG) exhibit a strong distance dependence for n < 4, and a weak distance dependence for n ≥ 4. We also predict conditions under which oscillatory or non-oscillatory charge transfer (CT) yield are expected.
Cite this ArticleCrossMarkPublonsHarvard Library HOLLISGrowKudosResearchGateBase SearchOAI PMHAcademic MicrosoftScilitSemantic ScholarUniversite de ParisUW LibrariesSJSU King LibrarySJSU King LibraryNUS LibraryMcGillDET KGL BIBLiOTEKJCU DiscoveryUniversidad De LimaWorldCatVU on WorldCat

Let us start an epidemic by giving away kindness

Published on: 4th July, 2019

OCLC Number/Unique Identifier: 8186247177

Patients were left in soiled sheets or sitting on commodes for hours. Some patients needing pain relief got it late or not at all.’ These were a sample of the findings in the Francis Report which revealed severe failings in patient care in the Mid Staffordshire NHS Foundation Trust in the UK. Recommendations in the Francis Report included the need to recruit compassionate staff and having compassion training for clinicians [1].
Cite this ArticleCrossMarkPublonsHarvard Library HOLLISGrowKudosResearchGateBase SearchOAI PMHAcademic MicrosoftScilitSemantic ScholarUniversite de ParisUW LibrariesSJSU King LibrarySJSU King LibraryNUS LibraryMcGillDET KGL BIBLiOTEKJCU DiscoveryUniversidad De LimaWorldCatVU on WorldCat

Non-force electromagnetic fields

Published on: 9th March, 2020

OCLC Number/Unique Identifier: 8558604059

The non-force magnetic fields were first predicted by Chandrasekhar in 1956 in his well-known published work [1]. Since then there have appeared a large number of theoretical studies [5,6,15,17] with the research into various aspects of physical manifestations of non-force magnetic fields. However by now their existence in the technical physics and in laboratory experiments has not been experimentally confirmed [30]. Nevertheless the indistinct presence on the Earth of such fields was, in a sense, discovered in the natural electromagnetic field much earlier.
Cite this ArticleCrossMarkPublonsHarvard Library HOLLISGrowKudosResearchGateBase SearchOAI PMHAcademic MicrosoftScilitSemantic ScholarUniversite de ParisUW LibrariesSJSU King LibrarySJSU King LibraryNUS LibraryMcGillDET KGL BIBLiOTEKJCU DiscoveryUniversidad De LimaWorldCatVU on WorldCat

Connected Health Apps and Devices: Implications for Healthcare Delivery

Published on: 25th June, 2019

OCLC Number/Unique Identifier: 8172451194

Healthcare is realizing the importance of health information technology - its applications and devices in play today. Advancing healthcare best practices will rely on up to date data and analysis to provide the most effective forms of therapy. Healthcare is becoming more reliant on patients who are engaging in their own healthcare. With this we are seeing an increase in available health related apps for these devices. This summary reviews various connected health strategies using proven apps and devices to improving the quality of care, promoting patient engagement, and improving outcomes. Here we discuss several trends and the healthcare delivery implications.
Cite this ArticleCrossMarkPublonsHarvard Library HOLLISGrowKudosResearchGateBase SearchOAI PMHAcademic MicrosoftScilitSemantic ScholarUniversite de ParisUW LibrariesSJSU King LibrarySJSU King LibraryNUS LibraryMcGillDET KGL BIBLiOTEKJCU DiscoveryUniversidad De LimaWorldCatVU on WorldCat
Help ?

HSPI: We're glad you're here. Please click "create a new Query" if you are a new visitor to our website and need further information from us.

If you are already a member of our network and need to keep track of any developments regarding a question you have already submitted, click "take me to my Query."